SC800
Security System
Features
8
EOLR supervised zones (expandable to 16 zones)
Real
time clock
21
event Alarm History with time and date stamp
Split
reporling and backup reporting with three different phone
numbers
16
user codes
Opening/closing
by user
4
parlitions with common zone capability, 4 separate entrance/exit delay
times
The
system may be divided by user, zone and keypad
Individually
controlled partition accounts with arm/disarm
Two
independent Test Timers
Opening/Closing
reports by exception. with programmable window and holiday
schedule
Four
methods of programming
1
Download from the central station
2
Program locally from the LCD keypad
3
Copy PROM
Ring
detector and answering machine bypass
DOB
Data Output Board
The
optional DOB board provides eight additional open collector outputs to the basic
control panel. Programmable outputs are
Remole
Buzzer
Door
Strike
Strobe
light output
Courtesy
Arm/Alarm
Ready/Trouble
Smoke
Power
Fire/Burg
Bell
Description
The
Arrowhead SC800 is an EEPROM based, udloading/ downloading control communicator. Eight
EOL resistor supervised zones can be expanded to 16 zones with the optional
EEM-8 Upgrade Module. Zones can be indiviclually programmed for audible/silent
panic, instant/delay/follower burglary or household fire (not UL listecd for
commercial fire). The system may be programmed using the SK1L keypad or remotely
downloaded from IBM-compatible computers using ScanPro Downloader software. The
SC800 also features a convenient Copy PROM capability. Each SC800 comes in a
steel enclosure with lock and EEPROM. The SC800 is compatible with the optional
EKP1 LED (for operation and zone status only) or SK1L LCD keypad (full
functionality).
Built-in
Digital Communicator
The
SC800's built-in communicator reports to three separate phone numbers, allowing
split reporling or backup reporting with up to 3 different account numbers. The
communicator reports all standard pulse reporting formats, including Silent
Knight4+2 and Arrowhead Extended Superfast4+3+3.
Keypad
controlled user functions
Arming/Disarming
Bypass
zones individually or by group (2 groups)
System
test
InstantlDelay
Four
emergency24-hour keypad activated functions
Duress,
Smoke detector reset, Chime Feature
Set
Time/Date, entrance/exit delays
Digital
Communicator Features
Three
or four digit account numbers
Programmable
reporting attempts
Failure
to communicate annunciation at keypad
Zone
bypass reporting
Extended,
Superfast 4+3+3, Silent Knight 4+2, as well as standard reporting
format
Reporting
delay by zone
Alarms,
Trouble, Restoral reports by zone
Test
timer reporting
Programmable
Software Features
"Follower"
zones
Single
user, partitioned and multi-premise operation
Opening/closing
reports by exception
10-day
holiday schedule
Closing
by exception pre-warn signal
Programmable
loop response time, 10 to 500 ms
Aulo
test report to any combination of 3 phone numbers
Dynamic
low battery/restoral reporting with programming reporting
delays
False
alarm shutdown by zone
Software
delete of EOL resistors
Remotely
shut down nonpaying accounts
Remote
high speed up/downloading from IBM-compatible PC with ScanPro Downloader
software
---
Specifications
Input
power requirements:
16 5-18VAC, 20VA
Standby
Battery:
12Volt rechargeable gel-type (not supplied)
Temperature
operating range:
32( to 120( F(
Auxiliary
power output:
12VDC regulated, 600 MA
BELL
Outpot:
Burglary and fire output, 12 VDC
Loop
response:
10-500 mSec (1 second wllen dialing)
Maximum
loop resistance:
Not to exceed 300 Ohms on any loop (EOL resistor not
included)
Transient
and Lightning Protection:
Lighting and surge protection on all input, power and telephone
lines
Dimensions:
13.2" H x 13.2" W x 3.5"D
Shipping
weight:
9 lbs
FCC
registration no.:
4T2USA-24862-AL-E
Ringer
Equivalence:
0.lB
Listings:
UL985, UL 1023, UL 1635, CSFM
Order
Information
SC800:
SC800 control with 1 PHK8 parts packet including spare fuses, and metal
enclosure with key lock.
SKIL
Backlit
LCD keypad (1xl6). Oversize keys. Hinged cover for aux
keys.
Dimensions:
6.570" X4.670"X1.100"
EKP1
LED
keypad Zone status, alarm memory, instant, delay arm
status
Dimensions:
4.680"X6.58O"X1.200"
DOB
Data Output Board:
5 data output boards: 2 for Zone outputs; 1 for system status; 1 for (4)
bell/special outputs
EEM-8
Expansion Module:
This field-installable, plug-in module upgrades the 8 zones to 16 zones.
Includes 1 E-EEP
E-EEP
EEPROM:
Use to upgrade event flislory to 60 evemts and users to 30