SC800 Security System

 

Features

8 EOLR supervised zones (expandable to 16 zones)

Real time clock

21 event Alarm History with time and date stamp

Split reporling and backup reporting with three different phone numbers

16 user codes

Opening/closing by user

4 parlitions with common zone capability, 4 separate entrance/exit delay times

The system may be divided by user, zone and keypad

Individually controlled partition accounts with arm/disarm

Two independent Test Timers

Opening/Closing reports by exception. with programmable window and holiday schedule

Four methods of programming

1 Download from the central station

2 Program locally from the LCD keypad

3 Copy PROM

Ring detector and answering machine bypass

 

DOB Data Output Board

The optional DOB board provides eight additional open collector outputs to the basic control panel. Programmable outputs are

Remole Buzzer

Door Strike

Strobe light output

Courtesy

Arm/Alarm

Ready/Trouble

Smoke Power

Fire/Burg Bell

 

Description

 

The Arrowhead SC800 is an EEPROM based, udloading/  downloading control communicator. Eight EOL resistor supervised zones can be expanded to 16 zones with the optional EEM-8 Upgrade Module. Zones can be indiviclually programmed for audible/silent panic, instant/delay/follower burglary or household fire (not UL listecd for commercial fire). The system may be programmed using the SK1L keypad or remotely downloaded from IBM-compatible computers using ScanPro Downloader software. The SC800 also features a convenient Copy PROM capability. Each SC800 comes in a steel enclosure with lock and EEPROM. The SC800 is compatible with the optional EKP1 LED (for operation and zone status only) or SK1L LCD keypad (full functionality).

 

Built-in Digital Communicator

 

The SC800's built-in communicator reports to three separate phone numbers, allowing split reporling or backup reporting with up to 3 different account numbers. The communicator reports all standard pulse reporting formats, including Silent Knight4+2 and Arrowhead Extended Superfast4+3+3.

 

 

 

 

Keypad controlled user functions

Arming/Disarming

Bypass zones individually or by group (2 groups)

System test

InstantlDelay

Four emergency24-hour keypad activated functions

Duress, Smoke detector reset, Chime Feature

Set Time/Date, entrance/exit delays

 

Digital Communicator Features

Three or four digit account numbers

Programmable reporting attempts

Failure to communicate annunciation at keypad

Zone bypass reporting

Extended, Superfast 4+3+3, Silent Knight 4+2, as well as standard reporting format

Reporting delay by zone

Alarms, Trouble, Restoral reports by zone

Test timer reporting

 

Programmable Software Features

"Follower" zones

Single user, partitioned and multi-premise operation

Opening/closing reports by exception

10-day holiday schedule

Closing by exception pre-warn signal

Programmable loop response time, 10 to 500 ms

Aulo test report to any combination of 3 phone numbers

Dynamic low battery/restoral reporting with programming reporting delays

False alarm shutdown by zone

Software delete of EOL resistors

Remotely shut down nonpaying accounts

Remote high speed up/downloading from IBM-compatible PC with ScanPro Downloader software

 

---

 

 Specifications

 

Input power requirements: 16 5-18VAC, 20VA

Standby Battery: 12Volt rechargeable gel-type (not supplied)

Temperature operating range: 32( to 120( F(

Auxiliary power output: 12VDC regulated, 600 MA

BELL Outpot: Burglary and fire output, 12 VDC

Loop response: 10-500 mSec (1 second wllen dialing)

Maximum loop resistance: Not to exceed 300 Ohms on any loop (EOL resistor not included)

Transient and Lightning Protection: Lighting and surge protection on all input, power and telephone lines

Dimensions: 13.2" H x 13.2" W x 3.5"D

Shipping weight: 9 lbs

FCC registration no.: 4T2USA-24862-AL-E

Ringer Equivalence: 0.lB

Listings: UL985, UL 1023, UL 1635, CSFM

 

Order Information

 

SC800: SC800 control with 1 PHK8 parts packet including spare fuses, and metal enclosure with key lock.

SKIL

Backlit LCD keypad (1xl6). Oversize keys. Hinged cover for aux keys.

Dimensions: 6.570" X4.670"X1.100"

EKP1

LED keypad Zone status, alarm memory, instant, delay arm status

Dimensions: 4.680"X6.58O"X1.200"

DOB Data Output Board: 5 data output boards: 2 for Zone outputs; 1 for system status; 1 for (4) bell/special outputs

EEM-8 Expansion Module: This field-installable, plug-in module upgrades the 8 zones to 16 zones. Includes 1 E-EEP

E-EEP EEPROM: Use to upgrade event flislory to 60 evemts and users to 30