| Check |
Device |
Enabled by |
| 100 |
RF Receiver |
*56 zone programming: input device
type entry |
| 103 |
Long Range Radio |
automatic if output to long range
radio field *29 enabled |
| 104 |
4286 Voice Module |
automatic if phone module access
code field *28 enabled |
| 107 |
Zone Expander Module 1 |
*56 zone programming: input device
type entry, then: automatic if zone no. 9-16 entered as AW type or relay assigned |
| 108 |
Zone Expander Module 2 |
*56 zone programming: input device
type entry, then: automatic if zone no. 17-24 entered as AW type or relay assigned |
| 109 |
Zone Expander Module 3 |
*56 zone programming: input device
type entry, then: automatic if zone no. 25-32 entered as AW type or relay assigned |
| 110 |
Zone Expander Module 4 |
*56 zone programming: input device
type entry, then: automatic if zone no. 33-40 entered as AW type or relay assigned |
| 111 |
Zone Expander Module 5 |
*56 zone programming: input device
type entry, then: automatic if zone no. 41-48 entered as AW type or relay assigned |
| 112 |
Relay Module 1 |
*79 output device programming:
device address prompt: entered at device address prompt |
| 113 |
Relay Module 2 |
*79 output device programming:
device address prompt: entered at device address prompt |
| 114 |
Relay Module 3 |
*79 output device programming:
device address prompt: entered at device address prompt |
| 115 |
Relay Module 4 |
*79 output device programming:
device address prompt: entered at device address prompt |