This is a Radionics 7000-9000 series panel


All panels in this series operate almost identically and use the same programming handlers. The following info applies to all of these panels.

At A Glance

Arm
[Code] + [ENT] Shortcuts: [COMMAND][1] Arms All; [COMMAND][2] Arms Perimeter, entry zone is instant; [COMMAND][3] Arms Perimeter, entry zone delays.
Disarm
[Code] + [ENT]
Check Faulted Zones Press any numeric key [0-9] and keypad will scroll through faulted zones
Smoke Reset
After silencing alarm with [Code] + [ENT], press [COMMAND][4][7] to reset smoke detectors.
Code Change
[COMMAND][5][5]; Enter Old Code + [ENT]; Enter New Code + [ENT]; Enter New Code Again + [ENT]. (To ADD a code, [COMMAND][5][6]. To DELETE a code, [COMMAND][5][3].)
Chime Mode On/Off
[COMMAND][6]
Force Arm Over Bad Zones
[Code]; Keypad displays [CHK AREA X]; Press [NEXT] thru the list of all faulted points OR just press [COMMAND]. [FORCE ARM?] will display at the end of the list. Press [ENT].
Power Down Panel
Pull one wire on NP7-12 battery in panel. Disconnect AC power by pulling wire on terminal 1, upper left corner of panel.
View Faulted Zones
Press ANY NUMBER KEY on the keypad.  Faulted zones will scroll across keypad.

D1255 Keypad

D9000 series Installation Guide