Arm:
|
Code
|
DisArm:
|
Code |
Check Faulted
Zones
|
Press [ZONE DISPLAY] key. While
holding this button down, lights become zone lights. On is faulted, off
is normal, blinking is alarm memory.
|
Smoke Reset:
|
Press [CMND], then press [TEST RESET]. After 15
seconds, snoke detectors will reset.
|
Code Change:
|
Master code is burned onto the chip
and can only be changed by technician. User 1 and User 2 code can be
added at keypad. To add or change a temp code, [CODE] + master code + User # (1 or 2) + New 4 digit code.
|
Chime Mode
On/Off:
|
[CMND] + [CHIME] (9 key).
|
Bypass Zone(s):
|
[CMND] + [BYPASS] (6 key) + optionally zone(s) to bypass
+ [CMND]. Then enter
code to arm. If you leave out zone(s) to bypass, the panel will bypass
faulted zones automatically.
|
Power Down Panel:
|
Either uplug transformer or disconnect
terminal 4 or 5 on right side of panel board. Unplug one side of
battery (usually an NP4-12 installed).
|